Vacuum Technology Transactions. Proceedings of the Sixth by C. Robert Meissner

By C. Robert Meissner

Show description

Read Online or Download Vacuum Technology Transactions. Proceedings of the Sixth National Symposium PDF

Best technology books

Fabricated: The New World of 3D Printing

Fabricated tells the tale of 3D printers, humble production machines which are bursting out of the manufacturing facility and into colleges, kitchens, hospitals, even onto the style catwalk. Fabricated describes our rising international of printable items, the place humans layout and 3D print their very own creations as simply as they edit a web record.

Parametric Optimization: Singularities, Pathfollowing and Jumps

This quantity is meant for readers who, whether or not they be mathematicians, employees in different fields or scholars, are accustomed to the elemental methods and techniques of mathematical optimization. the subject material is anxious with optimization difficulties within which a few or all the person facts concerned depend upon one parameter.

Extra resources for Vacuum Technology Transactions. Proceedings of the Sixth National Symposium

Example text

This H 2 evolution is only in part caused by the reaction between H 2 0 and the oxide cathode. A comparison SCHMIDT taps, only 1 per cent of the water which had been let in could be found after a waiting time of 70 hr. In the case of a television picture tube with a 43 cm screen only one part in a thousand of the amount of H 2 0 let in flowed into the omegatron after waiting for 90 hr. In both cases a considerable amount of H 2 had collected in the test system. In gettered systems an initial H 2 0-partial pressure decreases in an even shorter time.

Side tube and ionization gauge were arranged physically so that they could be baked out in the same oven. S. source used was a "Diatron 20", a 180° analyzer of 1 cm radius, commercially available from Consolidated Electrodynamics Corporation. Its original mount was a metal flange which, however, could not be baked. For this reason, a new bakeable mounting system was designed, consisting of glass and a minimum of metal. Fig. S. source, and the 18-lead Kovar-glass press. ) ; q = number of electronic charges ; V = ion energy (eV) ; B = magnetic field intensity (G) ; r = radius of curvature (cm).

J. WARNECKE, Jr. omegatron which will be defined as the collected ion current for a flow of C 0 2 of 1 cm 3 , measured at normal temperature and pressure, per day. 3 X 10~ n A. As a matter of comparison, for the same flow of gas and under experimental conditions similar to those which have just been described, a conventional sector-field highperformance spectrometer (type SM 500 of the Compagnie Générale de T S F ) gives an ion current with C0 2 + of 1 5 x l 0 _ l o A for an ionizing current of 500 μΑ.

Download PDF sample

Rated 4.23 of 5 – based on 5 votes